Standard Features

AVANZINI BUILDERS, INC.

“CITRUS HILLS AREA”

DISTINCTIVE FEATURES AND SPECIFICATIONS
(OUR HIGH ENERGY EFFICIENT HOMES)

SITE WORK AND FOUNDATION

  • LOT IN CITRUS HILLS AREA
  • ALL REQUIRED BUILDING PLANS
  • ALL REQUIRED BUILDING PERMITS
  • ALL REQUIRED ZONING APPROVAL
  • ALL REQUIRED HEALTH PERMITS
  • CITRUS COUNTY IMPACT FEE OF $6,465.00
  • TREE REMOVAL TO PLACE HOUSE ON LOT
  • 8” X 16” -3000 P.S.I. CONCRETE FOOTER
  • 2 EACH- 5/8” STEEL RODS CONTINUOUS FOOTER
  • MONOLITHIC CONCRETE FLOOR
  • NON VEGETATION FOUNDATION FILL
  • TERMITE TREATED SOIL UNDER CONCRETE FLOOR
  • 6 MILL MOISTURE BARRIER UNDER CONCRETE FLOOR
  • COMMUNITY WATER AND SEPTIC TANK
  • FLORATAM SOD FOR 80 X 120 LOT
  • SPRINKLER SYSTEM FOR 80 X 120 LOT
  • PLANTS IN FROM OF HOME

PLUMBING

  • ALL PLUMBING WATER SUPPLY LINES ARE COPPER
  • ALL PLUMBING DRAIN LINES ARE PVC
  • PLUMBING FIXTURES IN STANDARD COLORS
  • NON-SKID FIBERGLASS SHOWER IN MASTER BATH (ANNA MARIA)
  • ELONGATED COMMODES
  • FIBERGLASS TUB OR SHOWER IN GUEST BATH
  • SOLID SURFACE VANITY TOPS W/ SOLID SURFACE SINKS IN BOTH BATHROOMS
  • SINGLE LEVER DELTA WASHERLESS FAUCETS W/ BRASS TRIM
  • DOUBLE BOWL CAST IRON 8” DEEP KITCHEN SINK OR STAINLESS STEEL
  • DELTA SINGLE LEVER WAHERLESS FAUCET W/ SPRAY IN KITCHEN W/ BRASS TRIM
  • RECESSED WALL CONNECTION FOR WASHER HOOK UP
  • VENTED DRYER HOOK UP
  • ICE MAKER IN KITCHEN
  • 3 EXTERIOR HOSE BIBS
  • 40 GALLON HIGH RECOVERY ENERGY EFFICIENT HOT WATER HEATER
  • WATER HEATER ON SHELF

STRUCTURAL

  • 4” 3000 P.S.I. CONCRETE FLOOR
  • FIBER MESH REINFORCING IN FLOOR
  • 8” X 16” CONCRETE BLOCK WALLS
  • CONCRETE WALLS REINFORCED W/ STEEL AND POURED W/ CONCRETE
  • ENGINEERED TRUSSES 24” ON CENTER
  • TRUSSES SECURED WITH HURRICANE STRAPS

CENTRAL HEATING AND AIR

  • TRANE ENERGY SAVING HEAT PUMP (AIR TO AIR) 13 SEER
  • ROUND SUPPLY DUCTS IN LIVING AREA
  • ADJUSTABLE AIR REGISTERS IN LIVING AREA
  • FIBERGLASS DUCT WORK FOR NOISE REDUCTION

ELECTRICAL

  • 200 AMP. BREAKER SERVICE
  • ALL WIRING INSIDE HOUSE FROM BREAKER PANEL IS COPPER
  • PRE-WIRED AND BRACED FOR CEILING FANS (5 EACH)
  • ROUGH IN EXTERIOR LIGHTS AT ENTRANCE
  • EXHAUST FANS IN BATHROOMS
  • DOOR CHIMES
  • 5 TV OUTLETS
  • 5 PHONE OUTLETS
  • 3 EXTERIOR 110 VOLT EXTERIOR OUTLETS
  • LIGHT FIXTURES BY BUILDER OR $1,100.00 ALLOWANCE
  • SMOKE DETECTORS ADJACENT TO BEDROOMS
  • SILENT ROCKER SWITCHES THROUGHOUT
  • WASHER AND DRYER OUTLETS
  • PRE-WIRED FOR GARAGE DOOR OPENER
  • GARAGE DOOR OPENER INCLUDED
  • ROUGH IN ATTIC LIGHT
  • ROUGH IN YARD LIGHT
  • WIRED FOR DISHWASHER
  • WIRED FOR DISPOSAL
  • WIRED FOR WATER HEATER TIMER (TIMER ADD $145.00)

INSULATION

  • R-30 INSULATION IN LIVING AREA CEILING
  • R-10.2 (3/4” HI-R) INSULATION ON EXTERIOR WALLS IN LIVING AREA
  • R-11 INSULATION BETWEEN GARAGE AND LIVING AREA
  • R-19 IN GARAGE AND SCREEN ROOM CEILINGS
  • RIDGE VENT FOR ATTIC VENTILATION
  • FULLY VENTED ALUMINUM SOFFIT

INTERIOR FRAMING

  • 2 X 4 PARTITION WALL STUDS INSTALLED 16” ON CENTER
  • PRESSURE TREATED LUMBER WHERE WOOD TOUCHES MASONARY
  • 1 X 2 PRESSURE TREATED FURRING ON BLOCK WALLS
  • 1 X 4 PRESSURE TREATED FURRING FOR BASE
  • 1 X 2 PRESSURE TREATED FURRING FOR FIRE STOPPING
  • WOOD BACKING FOR DRAPERY RODS
  • WOOD BACKING FOR CEILING FANS
  • PRE-ENGINEERED ROOF TRUSSES 24” ON CENTER
  • FIRE STOPPING AT ALL CEILINGS LESS THAN 7 FEET
  • FIRE STOPPING AT INSIDE OF TOP OF BLOCK WALL

ROOF

  • SELF-SEALING FIBERGLASS TIMBERLINE ARCHITECTURAL ASPHALT SHINGLES
  • ALUMINUM FASCIA
  • 1 FOOT 4 INCH FULLY VENTED ALUMINUM SOFFIT
  • 4 ALUMINUM COLORS AVAILABLE
  • PRE-ENGINEERED ROOF TRUSSES 24” ON CENTER
  • FULL 1/2" NOMINAL, 4 X 8 EXTERIOR ROOF SHEATING
  • 5/12 ROOF PITCH
  • ROOF RIDGE VENT AS NEEDED
  • CATHEDRAL CEILINGS AS PER PLAN
  • 9 FOOT 4 INCH CEILINGS IN REST OF HOUSE/PLAN

WINDOWS AND EXTERIOR DOORS

  • BOTTOM PANE WINDOWS POP IN FOR CLEANING
  • INSULATED DOUBLE PANE SINGLE HUNG WINDOWS
  • INSULATED DOUBLE PANE GLASS FRENCH DOORS
  • INSULATED STEEL FRONT DOOR
  • WHITE ALUMINUM WINDOW
  • SCREENS ON ALL WINDOWS
  • FULL WIDTH MARBLE SILLS IN LIVING AREA

INTERIOR WALLS

  • WALLS ARE 1/2" DRYWALL WITH KNOCK DOWN TEXTURES
  • ROUND CORNERS ON MOST DRYWALL CORNERS
  • CEILINGS 1/2" DRYWALL WITH SPANISH LACE TEXTURE
  • BATHROOM WET AREAS ARE 1/2" WATER RESISTANT DRYWALL
  • 2 COATS OF VINYL LATEX ON ALL WALLS AND CEILING THROUGH OUT HOME

HOUSE TRIM AND INTERIOR DOORS

  • INTERIOR DOORS ARE 6 PANEL COLONIAL
  • LIFETIME WARRANTY KWIKSET DOORLOCKS
  • DEADBOLT ON FRONT DOOR, SIDE GARAGE DOOR AND EXTERIOR SWING DOORS
  • BASEBOARD AND DOOR CASING ARE COLONIAL STYLE
  • CLOSET MAID VINYL COATED STEEL SHELVING
  • STEEL OVERHEAD GARAGE DOOR (7X16) OR (8X16)
  • 6 PANEL COLONIAL SMOOTH BACK BIFOLD COSET DOORS
  • KEYED DEADBOLT LOCK ON EXTERIOR DOORS
  • INTERIOR TRIM PAINTED
  • EXTERIOR BANDING TRIM OR BRICK TRIM ARE CEMENTUS COATING
  • EXTERIOR WALLS HAVE 2 COATS CEMENTUS COATING
  • STUCCO IS COVERED WITH 2 COATS OF VINYL LATEX PAINT
  • INSIDE GARAGE BLOCK WALLS ARE CEMENTUS COATED ON BLOCK

APPLIANCES

  • DELUXE SELF-CLEANING RANGE WITH GLASS TOP
  • BUILT-IN DISHWASHER WITH POT SCRUBBER FEATURE
  • MICROWAVE WITH HOOD DUCT THROUGH ROOF
  • GARBAGE DISPOSAL

CABINETS

  • HIDDEN HINGES ON KITCHEN CABINET DOORS
  • CUSTOM BUILT CABINETS WITH GRANITE OR CORIAN COUNTER TOPS IN KITCHEN
  • BATHROOM AND KITCHEN COUNTERS HAVE 4” BACK SPLASH
  • KITCHEN CABINET DOORS ARE COLONIAL
  • ADJUSTABLE SHELVES ARE VINYL FOR EASY CLEANING
  • CUSTOM BUILT MICA CABINETS IN BATHROOM WITH GRANITE OR CORIAN TOPS AND SINKS
  • BATHROOM CABINET DOORS ARE COLONIAL
  • CUSTOM BUILT CABINET IN BATHROOMS
  • CABINET HARDWARE BY BUILDER
  • FULL EXTENSION DRAW HARDWARE

CERAMIC TILE

  • CERAMIC TILE ON WALLS OF TUB AREA
  • CERAMIC TILE ON WALLS OF SHOWER AREA
  • CERAMIC TILE FLOORING IN BATHS
  • CERAMIC TILE FLOORING IN FOYER
  • CERAMIC TILE FLOORING IN KITCHEN AND NOOK
  • CERAMIC TILE FLOORING IN UTILITY ROOM
  • 4” GRANITE OR CORIAN KITCHEN BACK SPLASH
  • CERAMIC TILE ABOVE BACK SPLASH

FLOOR COVERINGS

  • UPGRADED WALL-TO-WALL CARPETING
  • REBOND PADDING W/ MOISTURE BARRIER UNDER CARPET

    DRIVEWAY AND WALKS
  • CONCRETE WALKWAY FROM DRIVE TO COVERED ENTRY
  • 3’ X 10’ CONCRETE PAD AT GARAGE SIDE
  • CONCRETE DRIVEWAY FROM GARAGE TO STREET

MISCELLANEOUS

  • PANTRY IN KITCHEN AS PER PLAN
  • DISAPPEARING STAIRS IN GARAGE

Updated May 2012